Abstract: | This paper demonstrates the microcontamination analysis on wafers after they went through the conventional ULSI processing steps, by using the vapor phase decomposition/total reflection X-ray fluorescence (VPD/TXRF) technique. It was found that the wafer location in the holding cassette during the chemical cleaning step affected the cleanness of the wafer, and the class 1 environment was not enough to keep the wafer to a contamination level below 5 x 10(9) atoms/cm(2) for three days storing, The breakdown characteristic of a gate oxide was shown to be closely related with the cleanness of the surface of the oxide. |