完整後設資料紀錄
DC 欄位語言
dc.contributor.authorChou, Chung-Cheen_US
dc.contributor.authorJao, Chih-Kaien_US
dc.date.accessioned2019-04-03T06:39:41Z-
dc.date.available2019-04-03T06:39:41Z-
dc.date.issued2010-11-01en_US
dc.identifier.issn8755-2930en_US
dc.identifier.urihttp://dx.doi.org/10.1193/1.3480275en_US
dc.identifier.urihttp://hdl.handle.net/11536/32034-
dc.description.abstractThis work investigates the seismic performance of rehabilitated steel moment connections using internal flange stiffeners (IFSs) welded to the face of a built-up box column and a beam flange inner side. The objective is to provide a rehabilitation scheme that excludes interference from the composite slab and story height limitation in an existing steel building. Five rehabilitated moment connections with different IFSs were tested according to AISC (2005) loading protocol to validate their cyclic performance. Two rehabilitated moment connections had excellent performance; no welded joint fractures were found in the connections with a drift in excess of 4%. The specimens were modeled using the computer program ABAQUS to further verify the effectiveness of the IFSs in transferring beam moments to a column and to investigate potential sources of connection failure. Design guidelines for the rehabilitation scheme are provided based on test and analytical results. [DOI: 10.1193/1.3480275]en_US
dc.language.isoen_USen_US
dc.titleSeismic Rehabilitation of Welded Steel Beam-to-Box Column Connections Utilizing Internal Flange Stiffenersen_US
dc.typeArticleen_US
dc.identifier.doi10.1193/1.3480275en_US
dc.identifier.journalEARTHQUAKE SPECTRAen_US
dc.citation.volume26en_US
dc.citation.issue4en_US
dc.citation.spage927en_US
dc.citation.epage950en_US
dc.contributor.department土木工程學系zh_TW
dc.contributor.departmentDepartment of Civil Engineeringen_US
dc.identifier.wosnumberWOS:000284547300002en_US
dc.citation.woscount6en_US
顯示於類別:期刊論文


文件中的檔案:

  1. 04b7d3c4ed59219c5af7d58b0bd8075e.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。