A multiple poly-oxide/poly-Si/SiO2/Si sandwiched structure is proposed for the conventional single incident angle and single wavelength ellipsometry measurement of the thicknesses and refractive indices of the poly-oxide and the poly-Si at the same time. The structure is simple and gives accurate results.