完整後設資料紀錄
DC 欄位語言
dc.contributor.author羅盛威en_US
dc.contributor.authorLo, Sheng-Weien_US
dc.contributor.author劉俊秀en_US
dc.contributor.author周中哲en_US
dc.contributor.authorLiou, Gin-Showen_US
dc.contributor.authorChou, Chung-Cheen_US
dc.date.accessioned2014-12-12T01:29:04Z-
dc.date.available2014-12-12T01:29:04Z-
dc.date.issued2011en_US
dc.identifier.urihttp://140.113.39.130/cdrfb3/record/nctu/#GT079616546en_US
dc.identifier.urihttp://hdl.handle.net/11536/42261-
dc.description.abstract本研究主要探討翼型鋼柱與鋼梁接合之梁翼內側加勁板接頭耐震行為,共進行四組實尺寸之梁柱接頭試驗,試體之鋼梁翼板與翼型柱採全滲透焊道接合,梁腹板則與柱剪力板以摩阻型螺栓接合。四組試體中,其中一組為傳統梁柱接頭,另外三組為梁翼內側加勁板補強接頭,其參數變化分別為加勁板厚度、加勁板形狀以及鋼梁材質的改變,此三組補強接頭於試驗後其韌性行為良好,滿足AISC(2005)耐震設計規範所要求的位移歷時至4%弧度層間側位移角。本研究並利用非線性有限元素分析程式ABAQUS(2003)模擬接頭試驗結果,並運用各項參數來探討接頭在地震力作用下可能之破壞位置。zh_TW
dc.description.abstractThe research presents test and finite element analysis results of steel wide flange column-to-beam connections using internal flange stiffeners (IFS). Four full-scale moment connections were tested. All specimens had bolted web connection and welded beam-to-column flange using complete joint penetration welds. One specimen without internal flange stiffeners was tested as a benchmark. Three rehabilitated moment connections had different shape stiffeners and beam material. All rehabilitated moment connections showed excellent performance under the AISC (2005) seismic loads in excess of 4% drift. All specimens were also modeled using the computer program ABAQUS (2003) for the correlation study.en_US
dc.language.isozh_TWen_US
dc.subject梁翼內側加勁板zh_TW
dc.subject梁柱接頭zh_TW
dc.subject翼型鋼柱zh_TW
dc.subjectInternal Flange Stiffenersen_US
dc.subjectColumn-to-Beam Connectionsen_US
dc.subjectSteel Wide Flangeen_US
dc.title翼型鋼柱與鋼梁加勁式接頭耐震行為zh_TW
dc.titleSeismic Performance of Steel Wide Flange Column-to-Beam Connections Using Internal Flange Stiffenersen_US
dc.typeThesisen_US
dc.contributor.department土木工程學系zh_TW
顯示於類別:畢業論文