Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chiou, CB | en_US |
dc.contributor.author | Lu, DC | en_US |
dc.contributor.author | Wang, CC | en_US |
dc.date.accessioned | 2014-12-08T15:01:41Z | - |
dc.date.available | 2014-12-08T15:01:41Z | - |
dc.date.issued | 1997-07-01 | en_US |
dc.identifier.issn | 0145-7632 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/483 | - |
dc.description.abstract | Pool boiling data for binary mixtures of R-22/R-124 on plain tubes are reported at reduced pressures of 0.1, 0.15, and 0.2. Significant reductions of heat transfer coefficients for mixtures are found as compared to pure refrigerant, and the reduction of heat transfer coefficient is especially pronounced in the vicinity of the pore component. This phenomenon is strongly related to the nonlinear variation of physical properties of liquid viscosity and latent heat of the mixtures. The available empirical and semiempirical correlations developed for mixtures are compared with the present data. In addition, a correlation based on the present R-22/R-124 experimental data is proposed. This correlation not only predicts the deterioration of heat transfer coefficients for the present data with success but also predicts the experimental data from other investigators with reasonably good accuracy. | en_US |
dc.language.iso | en_US | en_US |
dc.title | Investigations of pool boiling heat transfer of binary refrigerant mixtures | en_US |
dc.type | Article | en_US |
dc.identifier.journal | HEAT TRANSFER ENGINEERING | en_US |
dc.citation.volume | 18 | en_US |
dc.citation.issue | 3 | en_US |
dc.citation.spage | 61 | en_US |
dc.citation.epage | 72 | en_US |
dc.contributor.department | 機械工程學系 | zh_TW |
dc.contributor.department | Department of Mechanical Engineering | en_US |
Appears in Collections: | Articles |
Files in This Item:
If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.