標題: | Increase in intrathoracic volume in pectus excavatum patients after the Nuss procedure |
作者: | Chang, Pei-Yeh Hsu, Zhen-Yu Lai, Jin-Yao Wang, Chao-Jan Ching, Yu-Tai 機械工程學系 資訊工程學系 Department of Mechanical Engineering Department of Computer Science |
關鍵字: | Pectus excavatum;Intrathoracic volume;Pulmonary function;Nuss procedure;Finite element model |
公開日期: | 1-Feb-2010 |
摘要: | In this study, we present finite element analysis models to calculate the increase in intrathoracic volume of pectus excavatum patients after the Nuss procedure. One virtue of our approach is that the measurement of the intrathoracic volume has no time difference and is not affected by postoperative pain, which cannot be achieved with a 2-year difference between pre- and postoperative pulmonary function testing or any other clinical method. The calculations show that the intrathoracic volume of pectus excavatum patients increased by approximately 2.72-8.88% after the Nuss procedure. The increment curve was patient-dependent, although the increment behavior was similar among the six patients examined. The curve of the increase became flat when the elevating force exceeded 80 N or the displacement of the lower sternal end exceeded 2.6 cm in half of our cases. |
URI: | http://dx.doi.org/10.1007/s11517-009-0570-9 http://hdl.handle.net/11536/5884 |
ISSN: | 0140-0118 |
DOI: | 10.1007/s11517-009-0570-9 |
期刊: | MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING |
Volume: | 48 |
Issue: | 2 |
起始頁: | 133 |
結束頁: | 137 |