完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Jao, Jo-Chi | en_US |
dc.contributor.author | Lu, Hsiang-Chin | en_US |
dc.contributor.author | Lu, Hsin-Ying | en_US |
dc.contributor.author | Wang, Yun-Ming | en_US |
dc.contributor.author | Liu, Gin-Chung | en_US |
dc.contributor.author | Lin, Li-Min | en_US |
dc.contributor.author | Chu, Pei-Yu | en_US |
dc.contributor.author | Chen, Shih-Hsie | en_US |
dc.contributor.author | Chen, Po-Chou | en_US |
dc.date.accessioned | 2014-12-08T15:07:46Z | - |
dc.date.available | 2014-12-08T15:07:46Z | - |
dc.date.issued | 2010 | en_US |
dc.identifier.issn | 1609-0985 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/6113 | - |
dc.description.abstract | [Gd(TTDA-BOM)](2-) is a newly developed paramagnetic contrast agent. The aim of this study was to investigate the magnetic resonance imaging (MRI) behavior of [Gd(TTDA-BOM)](2-) in mice with implanted AS-30D (Chang hepatoma ascites, CHA) tumor in liver at a 3T high-field whole-body magnetic resonance (MR) scanner. The high-field MR scanner is expected to have a higher signal-to-noise ratio (SNR). The dynamic MRI studies show that the signal enhancement in liver is larger than that in tumor, so that the contrast-to-noise ratio (CNR) between liver and tumor increases after [Gd(TTDA-BOM)](2-) injection. During one-hour investigation, it was found that [Gd(TTDA-BOM)](2-) could stay in liver up to one hour. On the contrary, [Gd(DTPA)](2-) , a kind of commercial contrast agent, was excreted from liver quickly. Therefore, the CNR between liver and tumor using [Gd(TTDA-BOM)](2-) is larger than that using [Gd(DTPA)](2-) and remains high at least up to one hour. In conclusion, [Gd(TTDA-BOM)](2-) might have good potential for being a hepatobiliary MR contrast agent. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | Magnetic resonance imaging (MRI) | en_US |
dc.subject | Paramagnetic contrast agent | en_US |
dc.subject | Gd(TTDA-BOM) | en_US |
dc.subject | Liver | en_US |
dc.subject | Tumor | en_US |
dc.subject | 3T | en_US |
dc.title | The Imaging Behavior of an MRI Contrast Agent [Gd(TTDA-BOM)](2-) in a Mice Liver Tumor Model at 3 Tesla | en_US |
dc.type | Article | en_US |
dc.identifier.journal | JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING | en_US |
dc.citation.volume | 30 | en_US |
dc.citation.issue | 3 | en_US |
dc.citation.spage | 139 | en_US |
dc.citation.epage | 144 | en_US |
dc.contributor.department | 生物科技學系 | zh_TW |
dc.contributor.department | Department of Biological Science and Technology | en_US |
dc.identifier.wosnumber | WOS:000280727600003 | - |
dc.citation.woscount | 0 | - |
顯示於類別: | 期刊論文 |