完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Chiou, C. B. | en_US |
dc.contributor.author | Lu, D. C. | en_US |
dc.contributor.author | Liao, C. Y. | en_US |
dc.contributor.author | Su, Y. Y. | en_US |
dc.date.accessioned | 2014-12-08T15:09:23Z | - |
dc.date.available | 2014-12-08T15:09:23Z | - |
dc.date.issued | 2009-06-01 | en_US |
dc.identifier.issn | 1359-4311 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1016/j.applthermaleng.2008.09.004 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/7164 | - |
dc.description.abstract | In this article, the experiment is carried out with four stages of test section and new experimental data of non-azeotropic refrigerant mixtures R-22/R-124 are presented. Existing correlations are analysed and new ones are proposed for pure refrigerants. The nucleate boiling correlation of the refrigerant mixtures is modified so as to obtain the evaporation heat transfer coefficient of the refrigerant mixtures in a smooth tube. The result shows that the majority of the predictions fall within +/- 30% of the experiments. (c) 2008 Elsevier Ltd. All rights reserved. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | Forced convective boiling | en_US |
dc.subject | Evaporation | en_US |
dc.subject | Non-azeotropic | en_US |
dc.subject | Zeotropic | en_US |
dc.subject | Refrigerant mixtures | en_US |
dc.title | Experimental study of forced convective boiling for non-azeotropic refrigerant mixtures R-22/R-124 in horizontal smooth tube | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/j.applthermaleng.2008.09.004 | en_US |
dc.identifier.journal | APPLIED THERMAL ENGINEERING | en_US |
dc.citation.volume | 29 | en_US |
dc.citation.issue | 8-9 | en_US |
dc.citation.spage | 1864 | en_US |
dc.citation.epage | 1871 | en_US |
dc.contributor.department | 機械工程學系 | zh_TW |
dc.contributor.department | Department of Mechanical Engineering | en_US |
dc.identifier.wosnumber | WOS:000264887200055 | - |
dc.citation.woscount | 3 | - |