dc.description.abstractThree series of six full-scale, cyclic tests on post-tensioned (PT) beam-to-column connections were conducted to evaluate the cyclic performance. Each specimen represented an interior connection with steel beams PT to a column; one specimen also incorporated a composite slab. Reduced Flange Plates (RFPs) were added at the beam-to-column interface for energy dissipation, and flange reinforcing plates were provided outside the beam flanges to minimize yielding upon decompression. This paper describes the durability of the proposed connection, the effects of web stiffeners on beam local buckling, and the interaction of a composite slab. The first test series demonstrated that as long as beam yielding could be prevented before an interstory drift of 4%, the PT connection was capable of reaching an interstory drift of 5% or experiencing the AISC seismic loads twice without beam buckling. The second test series showed that beam buckling could be prevented by utilizing web stiffeners instead of increasing the length of the flange reinforcing plate. The third test series included a matched pair of specimens, one bare steel beam and one including a composite slab. Results that emphasize the influence of the composite slab on re-centering behavior and specific comments on the slab response were presented. The presence of a composite slab corresponded to higher-achieved moments due to the tensile capacities of the metal deck flutes, wire mesh, and longitudinal reinforcement, which were placed parallel to the PT beam. However, the re-centering behavior could be maintained after fractures of the wire mesh in the proposed slab details. Estimates of beam moments considering the presence of a composite slab were presented based on the cyclic test results. (C) 2008 Elsevier Ltd. All rights reserved.en_US
dc.language.isoen_USen_US
dc.subjectSteel post-tensioned connectionen_US
dc.subjectReduced flange plateen_US
dc.subjectCyclic testen_US
dc.subjectComposite slaben_US
dc.titleSeismic design and behavior of post-tensioned steel connections including effects of a composite slaben_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.engstruct.2008.04.013en_US
dc.identifier.journalENGINEERING STRUCTURESen_US
dc.citation.volume30en_US
dc.citation.issue11en_US
dc.citation.spage3014en_US
dc.citation.epage3023en_US
dc.contributor.department土木工程學系zh_TW
dc.contributor.departmentDepartment of Civil Engineeringen_US
dc.identifier.wosnumberWOS:000261307300006-
dc.citation.woscount19-
顯示於類別:期刊論文


文件中的檔案:

  1. 000261307300006.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。