完整後設資料紀錄
DC 欄位語言
dc.contributor.authorLiao, Lun-Deen_US
dc.contributor.authorWang, I-Janen_US
dc.contributor.authorChen, Sheng-Fuen_US
dc.contributor.authorChang, Jyh-Yeongen_US
dc.contributor.authorLin, Chin-Tengen_US
dc.date.accessioned2014-12-08T15:11:28Z-
dc.date.available2014-12-08T15:11:28Z-
dc.date.issued2011-06-01en_US
dc.identifier.issn1424-8220en_US
dc.identifier.urihttp://dx.doi.org/10.3390/s110605819en_US
dc.identifier.urihttp://hdl.handle.net/11536/8802-
dc.description.abstractIn the present study, novel dry-contact sensors for measuring electro-encephalography (EEG) signals without any skin preparation are designed, fabricated by an injection molding manufacturing process and experimentally validated. Conventional wet electrodes are commonly used to measure EEG signals; they provide excellent EEG signals subject to proper skin preparation and conductive gel application. However, a series of skin preparation procedures for applying the wet electrodes is always required and usually creates trouble for users. To overcome these drawbacks, novel dry-contact EEG sensors were proposed for potential operation in the presence or absence of hair and without any skin preparation or conductive gel usage. The dry EEG sensors were designed to contact the scalp surface with 17 spring contact probes. Each probe was designed to include a probe head, plunger, spring, and barrel. The 17 probes were inserted into a flexible substrate using a one-time forming process via an established injection molding procedure. With these 17 spring contact probes, the flexible substrate allows for high geometric conformity between the sensor and the irregular scalp surface to maintain low skin-sensor interface impedance. Additionally, the flexible substrate also initiates a sensor buffer effect, eliminating pain when force is applied. The proposed dry EEG sensor was reliable in measuring EEG signals without any skin preparation or conductive gel usage, as compared with the conventional wet electrodes.en_US
dc.language.isoen_USen_US
dc.subjectelectroencephalography (EEG)en_US
dc.subjectdry electrodeen_US
dc.subjectconductive gelsen_US
dc.subjectskin-sensor interface impedanceen_US
dc.titleDesign, Fabrication and Experimental Validation of a Novel Dry-Contact Sensor for Measuring Electroencephalography Signals without Skin Preparationen_US
dc.typeArticleen_US
dc.identifier.doi10.3390/s110605819en_US
dc.identifier.journalSENSORSen_US
dc.citation.volume11en_US
dc.citation.issue6en_US
dc.citation.spage5819en_US
dc.citation.epage5834en_US
dc.contributor.department影像與生醫光電研究所zh_TW
dc.contributor.department資訊工程學系zh_TW
dc.contributor.department電機工程學系zh_TW
dc.contributor.departmentInstitute of Imaging and Biomedical Photonicsen_US
dc.contributor.departmentDepartment of Computer Scienceen_US
dc.contributor.departmentDepartment of Electrical and Computer Engineeringen_US
dc.identifier.wosnumberWOS:000292026400018-
dc.citation.woscount21-
顯示於類別:期刊論文


文件中的檔案:

  1. 000292026400018.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。