完整後設資料紀錄
DC 欄位語言
dc.contributor.authorHsieh, Hong-Jungen_US
dc.contributor.authorLu, Tung-Wuen_US
dc.contributor.authorChen, Sheng-Changen_US
dc.contributor.authorChang, Chia-Minen_US
dc.contributor.authorHung, Chinghuaen_US
dc.date.accessioned2014-12-08T15:11:46Z-
dc.date.available2014-12-08T15:11:46Z-
dc.date.issued2011-04-01en_US
dc.identifier.issn0966-6362en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.gaitpost.2011.03.005en_US
dc.identifier.urihttp://hdl.handle.net/11536/9022-
dc.description.abstractIn human motion analysis, in situ calibration of the force plate is necessary to improve the accuracy of the measured ground reaction force (GRF) and center of pressure (COP). Few existing devices are capable of both static and dynamic calibration of the usually non-linear GRF and COP errors, while are also easy to move and/or set up without damaging the building. The current study developed a small device (160 cm x 88 cm x 43 cm) with a mass of 50 kg, equipped with auxiliary wheels and fixing suction pads for rapid deployment and easy set-up. A PC-based controller enabled quick movement and accurate positioning of the applied force to the calibration point. Static calibration at 100 validation points and dynamic calibration of a force plate were performed using the device. After correction by an artificial neural network (ANN) trained with the static data from another 121 points, the mean errors for the GRF were all reduced from a maximum of 0.64% to less than 0.01%, while those for the COP were all reduced from a maximum of about 1.37 mm to less than 0.04 mm. For dynamic calibration, the mean errors for the GRF were reduced from a maximum of 0.46% to less than 0.28%, while those for the COP were reduced from a maximum of 0.95 mm to less than 0.11 mm. The results suggest that the calibration device with the ANN method will be useful for obtaining more accurate GRF and COP measurements in human motion analysis. (C) 2011 Elsevier B.V. All rights reserved.en_US
dc.language.isoen_USen_US
dc.subjectMotion analysisen_US
dc.subjectForce plateen_US
dc.subjectCalibrationen_US
dc.subjectCenter of pressureen_US
dc.titleA new device for in situ static and dynamic calibration of force platformsen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.gaitpost.2011.03.005en_US
dc.identifier.journalGAIT & POSTUREen_US
dc.citation.volume33en_US
dc.citation.issue4en_US
dc.citation.spage701en_US
dc.citation.epage705en_US
dc.contributor.department機械工程學系zh_TW
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.identifier.wosnumberWOS:000291139600033-
dc.citation.woscount6-
顯示於類別:期刊論文


文件中的檔案:

  1. 000291139600033.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。