標題: | Seismic self-centering steel beam-to-column moment connections using bolted friction devices |
作者: | Tsai, Keh-Chyuan Chou, Chung-Che Lin, Chi-Lon Chen, Pei-Ching Jhang, Sheng-Jhih 土木工程學系 Department of Civil Engineering |
關鍵字: | post-tensioned connection;self-centering;friction device |
公開日期: | 10-Apr-2008 |
摘要: | This paper first presents the force-deformation relationship of a post-tensioned (PT) steel beam-to-column connection constructed with bolted web friction devices (FDs). This paper then describes the test program conducted in the National Center for Research on Earthquake Engineering, Taiwan, on four bolted FDs and four full-scale PT beam-to-column moment connection subassemblies using the FDs. Tests confirm that (1) the hysteretic behavior of four bolted FDs is very stable, (2) the friction coefficient between the steel plate and the brass shim is about 0.34, (3) the proposed force-deformation relationships reasonably predict the experimental responses of the PT connections under cyclically increasing deformations up to a beam peak rotation of 0.05 rad, and (4) the decompression moments do not degrade as beam cyclic deformations increase. Copyright (C) 2007 John Wiley & Sons, Ltd. |
URI: | http://dx.doi.org/10.1002/eqe.779 http://hdl.handle.net/11536/9462 |
ISSN: | 0098-8847 |
DOI: | 10.1002/eqe.779 |
期刊: | EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS |
Volume: | 37 |
Issue: | 4 |
起始頁: | 627 |
結束頁: | 645 |
Appears in Collections: | Articles |
Files in This Item:
If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.