完整後設資料紀錄
DC 欄位語言
dc.contributor.authorChen, YHen_US
dc.contributor.authorLiao, WHen_US
dc.contributor.authorLee, CLen_US
dc.contributor.authorWang, YPen_US
dc.date.accessioned2014-12-08T15:16:40Z-
dc.date.available2014-12-08T15:16:40Z-
dc.date.issued2006-05-01en_US
dc.identifier.issn0098-8847en_US
dc.identifier.urihttp://dx.doi.org/10.1002/eqe.555en_US
dc.identifier.urihttp://hdl.handle.net/11536/12296-
dc.description.abstractRocking mechanism can be an effective means of seismic isolation, despite the fact that it is rarely conceived a possible alternative. In this study, the feasibility of utilizing a rocking mechanism for earthquake protection of slender viaduct pier structures is explored both analytically and experimentally. With a discontinuous interface between the pier footings and the underlying pile caps, a rocking system is designed to rock intermittently as the seismic overturning moment exceeds the restoring moment provided by gravity. During the rock mode, the resisting flexural moment in the pier is released while the earthquake load is counteracted by the rotational inertia with respect to the supporting foot, thus preventing the Columns from yielding. Analytical modelling of this non-linear dynamic system is derived with a numerical procedure developed based on the fourth-order Runge-Kutta-Nystrom method. A series of tests including the free rocking and seismic performance test, has been conducted using a 1:50 scaled-down model structure of a typical viaduct pier system. Both analytical and experimental results show that the rocking pier system (RPS) for seismic protection of viaduct pier structures is effective and stable, and the stronger the earthquake intensity the more pronounced the control efficiency. The concept of using rocking mechanism for seismic isolation of viaduct pier structures has been demonstrated feasible and promising. Nevertheless, practical issues such as prevention of overturning, foot damage due to impact, or possible sliding of the pier following impact need to be carefully dealt with in the design aspect. Copyright (C) 2006 John Wiley & Sons, Ltd.en_US
dc.language.isoen_USen_US
dc.subjectrocking mechanismen_US
dc.subjectseismic isolationen_US
dc.subjectseismic performance testsen_US
dc.titleSeismic isolation of viaduct piers by means of a rocking mechanismen_US
dc.typeArticleen_US
dc.identifier.doi10.1002/eqe.555en_US
dc.identifier.journalEARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICSen_US
dc.citation.volume35en_US
dc.citation.issue6en_US
dc.citation.spage713en_US
dc.citation.epage736en_US
dc.contributor.department土木工程學系zh_TW
dc.contributor.department防災與水環境研究中心zh_TW
dc.contributor.departmentDepartment of Civil Engineeringen_US
dc.contributor.departmentDisaster Prevention and Water Environment Research Centeren_US
dc.identifier.wosnumberWOS:000237376500005-
dc.citation.woscount11-
顯示於類別:期刊論文


文件中的檔案:

  1. 000237376500005.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。