Title: Boron removal with UTC-series reverse osmosis filtration
Authors: Chiang, Andrew Cheng-Ting
Lin, Justin Chun-Te
Wijayanti, Dewi Ratna
Lee, Duu-Jong
防災與水環境研究中心
Disaster Prevention and Water Environment Research Center
Keywords: Reverse osmosis;Boron rejection;TDS rejection;Seawaters
Issue Date: 1-Mar-2013
Abstract: This study compared performance on boron rejection in seawater reverse osmosis (SWRO) membrane filtration in a high pressure cross-flow cell. Real seawaters were sampled at the north, east and south coast of Taiwan and the intake ports of SWRO plants in Penghu and Matsu islands. Four types of flat-sheet RO membranes (SG from GE Osmonics and UTC80, UTC80A, and UTC80S from Toray Industries) were tested. Permeate flux, feed flow rate and boron concentrations at room temperature were recorded over testing time. The UTC-series membranes have better performance on both boron and sodium rejection than SG membrane at all tested pH's. Test data sets were available for the first time using SWRO membrane for boron rejection from seawaters in Taiwan. (c) 2012 Taiwan Institute of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
URI: http://dx.doi.org/10.1016/j.jtice.2012.11.011
http://hdl.handle.net/11536/150493
ISSN: 1876-1070
DOI: 10.1016/j.jtice.2012.11.011
Journal: JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS
Volume: 44
Begin Page: 317
End Page: 321
Appears in Collections:Articles