標題: A Fully Integrated Asymmetrical Shunt Switched-Capacitor DC-DC Converter With Fast Optimum Ratio Searching Scheme for Load Transient Enhancement
作者: Lin, Yen-Ting
Lai, Yan-Jiun
Chen, Hung-Wei
Yang, Wen-Hau
Ma, Yu-Sheng
Chen, Ke-Horng
Lin, Ying-Hsi
Lin, Shian-Ru
Tsai, Tsung-Yen
電控工程研究所
Institute of Electrical and Control Engineering
關鍵字: Asymmetrical shunt switched-capacitor (ASSC) converter;dc-dc converter;fast optimum ratio searching (FORS)
公開日期: 1-九月-2019
摘要: This paper presents a modified negator-based switched-capacitor (NSC) dc-dc converter to achieve fine-grained voltage conversion ratios. Based on a concept of reconfiguring several 2: 1 switched-capacitor (SC) converters in series and parallel at the last stage, the proposed asymmetrical shunt SC (ASSC) converter provides more controllable variables of forward gain and feedback gain to decide different power path interconnections and increase the available conversion ratios, with a little sacrifice of its slow switching limit output impedance. The switching loss of the bottom-plate parasitic capacitance in the ASSC converter is less than the switching loss of the NSC topology because the two moderate voltages instead of the power rail are fed to the last stage 2: 1 SC unit and reduce the voltage swing. The bottom-plate swapping prototype further reduces the parasitic loss at high conversion ratios. To handle a large number of conversion ratios in closed-loop regulation, the ASSC converter uses the fast optimum ratio searching (FORS) technique, which evaluates the transient voltage drop to quickly search for target ratios and reduce the transient recovery time. A three-stage ASSC converter achieving 187 conversion ratios is fully integrated in the test chip, which is fabricated in 0.25-mu m CMOS process with an active area of 7.14 mm(2). Furthermore, 2389 conversion ratios can be derived in theory for a four-stage ASSC converter. The proposed reconfigurable SC converter provides an output voltage range of 0.4 to 2.8 V under no load conditions, and greater than 80% power efficiency at an output voltage level of 0.9 to 1.5 V over a load range of 3 to 9.5 mA. Due to the FORS technique, the measured transient recovery time is reduced from 7 to 1.5 mu s in case of load current step of 7 mA.
URI: http://dx.doi.org/10.1109/TPEL.2018.2889870
http://hdl.handle.net/11536/152327
ISSN: 0885-8993
DOI: 10.1109/TPEL.2018.2889870
期刊: IEEE TRANSACTIONS ON POWER ELECTRONICS
Volume: 34
Issue: 9
起始頁: 9146
結束頁: 9157
顯示於類別:期刊論文