Full metadata record
DC FieldValueLanguage
dc.contributor.authorLin, CTen_US
dc.contributor.authorLiu, SHen_US
dc.contributor.authorWang, JJen_US
dc.contributor.authorWen, ZCen_US
dc.date.accessioned2014-12-08T15:41:07Z-
dc.date.available2014-12-08T15:41:07Z-
dc.date.issued2003-04-01en_US
dc.identifier.issn0018-9294en_US
dc.identifier.urihttp://dx.doi.org/10.1109/TBME.2003.809502en_US
dc.identifier.urihttp://hdl.handle.net/11536/27981-
dc.description.abstractIn oscillometry, oscillation amplitudes (OAs) embedded in the cuff pressure are drastically affected by a variety of artifacts and cardiovascular diseases, leading to inaccurate arterial blood pressure (ABP) measurement. The purpose of this paper is to improve the accuracy in the arterial pressure measurement by reducing interference in the OAs using a recursive weighted regression algorithm (RWRA). This method includes a fuzzy logic discriminator (FLD) and a recursive regression algorithm. The FLD is used to reduce the effect of artifacts caused by measurement motion disturbance or cardiovascular diseases, and to determine the truthfulness of the oscillation pulse. According to the truth degree, the relationship between the cuff pressure and OA is reconstructed using the regression algorithm. Because the regression method must utilize inverse matrix operation, which will be difficult to implement in an automatic or ambulatory monitor, the recursive regression method is proposed to solve this problem. To test the performance of this RWRA, 47 subjects underwent the ABP measurement using both the auscultation and the oscillometry combined with the RWRA. It was found that the average difference between the pooled blood pressures measured by the auscultation and those by the oscillometry combined with the RWRA was found to be only 4.9 mmHg. Clinical results demonstrated that the proposed RWRA is more robust than the traditional curve fitting algorithm (TCFA). We conclude that the proposed RWRA can be applied to effectively improve the accuracy of the oscillometric blood pressure measurement.en_US
dc.language.isoen_USen_US
dc.subjectblood pressureen_US
dc.subjectfuzzy logicen_US
dc.subjectoscillationen_US
dc.subjectoscillometryen_US
dc.subjectregressionen_US
dc.titleReduction of interference in oscillometric arterial blood pressure measurement using fuzzy logicen_US
dc.typeArticleen_US
dc.identifier.doi10.1109/TBME.2003.809502en_US
dc.identifier.journalIEEE TRANSACTIONS ON BIOMEDICAL ENGINEERINGen_US
dc.citation.volume50en_US
dc.citation.issue4en_US
dc.citation.spage432en_US
dc.citation.epage441en_US
dc.contributor.department電控工程研究所zh_TW
dc.contributor.departmentInstitute of Electrical and Control Engineeringen_US
dc.identifier.wosnumberWOS:000182426100004-
dc.citation.woscount22-
Appears in Collections:Articles


Files in This Item:

  1. 000182426100004.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.