Title: Influence of design and operation parameters on bag-cleaning performance of pulse-jet baghouse
Authors: Lu, HC
Tsai, CJ
環境工程研究所
Institute of Environmental Engineering
Issue Date: 1-Jun-1999
Abstract: In this study, a filter test system with clean new fabric bags was used to measure the pulse pressure and acceleration of the filter bag. Fabric acceleration and pulse pressure were used as an index of bag-cleaning intensity. The jet pump curves, which relate the flow rate through the venturi to the average developed pressure by the venturi, were determined by the similar system. The intersection of the jet pump curve and the bag operating line, which relates the pressure drop to flow rate across the bag during pulse-jet cleaning, is the system operating point that was used to predict the average pulse pressure in the bag during pulse-jet cleaning. Experimental results of this study show that a higher pulse pressure can be achieved without the venturi at the top of the bag for bag materials with low resistance coefficient. For bags with higher resistance coefficients, higher pulse pressure is obtained with a venturi installed at the top of the bag. The predicted pressure values are in good agreement with experimental data. Dimensional analysis for jet pump performance was developed to reduce the experimental data. The results show that the jet pump curves obtained under different operating conditions can be reduced to the same nondimensional curve, which can be used to facilitate the design and operation of a pulse-jet cleaning system.
URI: http://dx.doi.org/10.1061/(ASCE)0733-9372(1999)125:6(583)
http://hdl.handle.net/11536/31307
ISSN: 0733-9372
DOI: 10.1061/(ASCE)0733-9372(1999)125:6(583)
Journal: JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE
Volume: 125
Issue: 6
Begin Page: 583
End Page: 591
Appears in Collections:Articles


Files in This Item:

  1. 000080444000016.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.