标题: | 无线感测网路下基于所在房间位置之高效率室内定位技术 An Efficient Room-based Indoor Localization Scheme for Wireless Sensor Networks |
作者: | 邱奕铭 Chiu, Yi-Ming 王国祯 Wang, Kuo-Chen 资讯科学与工程研究所 |
关键字: | 室内;定位技术;无线感测网路;房间资讯;Localization;room-based;wireless sensor network;indoor environment |
公开日期: | 2008 |
摘要: | 随着无线网路及超大型积体电路技术的快速发展,有更多的无线感测网路应用,如利用无线感测网路来提供病患的位置资讯,以协助医疗照护就是很好的例子。在室内的环境中,提供所在房间位置资讯比提供位置座标资讯更有参考价值。虽然目前基于讯号强度之定位演算法可达到不错的准确度,但其利用座标资讯直接转换为房间资讯却常有一定程度的误差。在本论文中,我们提出在无线感测网路下基于所在房间位置之高效率室内定位技术,其主要目标为提供高准确率之房间定位资讯以及降低演算法的计算成本。本研究藉由地图资讯,限制标地物可移动的位置,并结合以座标资讯为基础之特征值比对演算法来减少无线网路多重路径讯号影响所造成房间位置资讯的误判,并降低定位误差。实验结果显示,在RADAR定位系统上应用我们的方法可以将房间资讯的定位准确度自69% 提升到94%,并且将定位误差由3.19公尺降低为2.24公尺。我们也与以提供房间位置资讯的定位演算法Signpost做比较,实验结果显示虽然我们的方法会比Signpost多了一秒的定位延迟时间,但在各种的干扰环境下,我们的房间资讯的定位准确度比Signpost增加20%。 With rapid advances in wireless and VLSI technologies, applications of wireless sensor networks (WSN), such as target localization in medical environments, are getting more and more popular. In an indoor environment, identifying a target in a logical area, such as a room is more meaningful than identifying a location represented by coordinates. In existing indoor localization algorithms, although their average location estimate errors may be low, they may not provide high accuracy room-level information, which is usually transformed from the predicted coordinates obtained by their localization algorithms. In this thesis, we present a room-based indoor localization scheme using a path-restricted room-level localization algorithm (PRLA) and a fingerprinting based technique for wireless sensor networks. The design of the proposed PRLA localization system meets two objectives. The first is high accuracy of room-level localization and the other is low computational overhead. Experimental results show that by applying our PRLA scheme to the RADAR system, it significantly improves its room-level hit rate from 69% to 94% and reduces the average error distance from 3.19 m to 2.24 m. In addition, the proposed PRLA scheme can be applied to any coordinate-based indoor location system to enhance its room-level hit rate and localization accuracy. We also compared the proposed PRLA with Signpost which is also a room-based localization scheme. Experimental results demonstrate that the delay time to enter a room of the proposed PRLA was one second more than that of Signpost; however the proposed PRLA is more reliable than Signpost because its average room-level hit rate is 20% better than Signpost’s in our experiment when we move around in the same room. |
URI: | http://140.113.39.130/cdrfb3/record/nctu/#GT079655569 http://hdl.handle.net/11536/43374 |
显示于类别: | Thesis |
文件中的档案:
If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.