標題: | 積體電路廢水毒性鑑定及毒性減量之研究 The Study of Toxicity Identification and Reduction Evaluation Procedure in Integrate Circuit Wastewater |
作者: | 黃筱涵 Huang,Hsiao-Han 陳重元 Chen,Chung-Yuan 環境工程系所 |
關鍵字: | 積體電路廢水;毒性鑑定評估;毒性減量評估;生物毒性;顯影液;Integrate Circuit Wastewater;toxicity identification evaluation (TIE);Toxicity reduction evaluation(TRE);biological toxicity;D.magna;Microtox;Tetramethylammonium hydroxide(TMAH) |
公開日期: | 2012 |
摘要: | 本研究係針對積體電路排放廢水,利用Microtox急毒性試驗及D.magna水蚤急毒性試驗檢測其生物毒性,並進行毒性鑑定(Toxicant Identification Evaluation, TIE)之探討,找出主要毒性物質來源,而後進行毒性減量評估(Toxicity Reduction Evaluation, TRE)。毒性鑑定結果顯示廢水主要毒性物質為過氧化氫、氨氮、總銅以及氟離子。經phase I各分離程序,以曝氣試驗、陽離子交換樹脂及陰陽離子交換樹脂等處理程序對於廢水毒性皆有良好的去除效果。其中以陰、陽離子交換樹脂串聯之分離程序可完全去除廢水毒性。有機毒物於phaseII 僅鑑定出異丙胺等含氮有機物質,其貢獻些微有機物毒性。由phase III毒性確認試驗結果得知,將毒性物質過氧化氫、氨氮、總銅及氟離子回添加於經離子交換樹脂處理之廢水,毒性結果與原始廢水一致。而對於有機物溶劑顯影液之生物毒性研究,若將其添加於合成廢水中,亦會發現毒性強度大幅提高。且根據本研究試驗結果顯示顯影液確實對於水生生物有危害性,對於D.magna EC50值 1.15 mg/L。於毒性減量研究,活性碳吸附並無法有效去除廢水毒性。而陰、陽離子交換樹脂串聯則有良好的廢水毒性去除效果。此外,由於製程排放廢水量大,且水質成份極為複雜。若需提升毒物鑑定之可靠性,應隨時掌控廢水性質及建立製程原物料使用清單與特定污染源出處。而毒性減量工作屬管末處理,在得知主要毒性物質後,若能由源頭製程生產線釋出毒性物質之處加強原物料用量的控管,以及針對高濃度污染物先行處理,應可大幅降低後續處理費用。 In this study, Microtox and Daphnia magna acute toxicity tests and toxicity identification evaluation procedures (TIE) were applied to identify causative toxicants in the effluents from integrated circuit industries. Toxicity reduction evaluation (TRE) process was conducted to remove the observed toxicity by eliminating toxicants from the effluent.Based on the TIE results, hydrogen peroxide、ammonia、copper and Flouride were identified as major toxicants in the raw wastewater. The above identification has been further verified by confirm tests. Aeration、cation ion exchange and mixed-bed ion exchange were found to be the most effective treatment processes. In addition, 2-PROPANAMINE and Tetramethylammonium hydroxide(TMAH) were suspected as toxic organic compounds which caused minor toxicity toward Daphnia magna. However, no attempt was made to confirm such suspicions because these organic toxicants have been effectively removed through TRE processes.Finally,the acute toxicity of integrated circuit industry effluent was completely removed by the toxicity reduction evaluation process (mixed-bed ion exchange) |
URI: | http://140.113.39.130/cdrfb3/record/nctu/#GT079919525 http://hdl.handle.net/11536/49690 |
Appears in Collections: | Thesis |