dc.identifier.urihttp://hdl.handle.net/11536/77446-
dc.description.abstract本研究進行兩組大尺寸梁柱接頭之反復載重試驗以探討其耐震性能。本研究之試體採用鋼梁與「受鋼筋混凝土包覆之箱型鋼柱」(簡稱包覆箱型鋼柱或SRC柱)接合之梁柱接頭。此種鋼梁與SRC柱接合之構造的主要特點,在於利用SRC柱之勁度、防火與抗壓強度方面的長處,又可以發揮鋼梁在韌性與施工便捷方面之優點。 本研究之試體均符合強柱弱梁之原則且梁柱接頭區之標稱剪力強度均大於該區之需求剪力強度,試體之斷面配置均符合我國SRC設計規範之要求。實驗結果顯示,由於SRC柱內之箱型鋼管斷面在X與Y向各有兩片腹板,故可以提供梁柱接頭區充分的剪力強度,並可抑制接頭區的剪力變形,使接頭區之混凝土保持良好狀態,並無明顯開裂之情形,進而確保插入SRC柱的鋼梁受到接頭區之鋼筋混凝土有效的束制,使得鋼梁的塑性鉸可以遠離銲道,最終在SRC柱之混凝土面外約15公分處發展出穩定且充分的塑性變形。換言之,SRC柱接頭區的鋼筋混凝土具有保護鋼骨梁柱接頭銲道的功能,該區的鋼筋混凝土成功的將鋼梁的塑性鉸逼離銲道,使鋼梁在SRC柱混凝土面外形成良好的塑性鉸。 本研究之梁柱接頭試體在反復載重作用下,可以發展出穩定且飽滿的遲滯迴圈(Hysteretic Loop)。兩組試體之鋼梁「塑性轉角」(Plastic Rotation Angle)達到5.4 % 和6.0 % 弧度,梁柱接頭之「層間變位角」(Interstory Drift Angle)達到6.2 % 與6.7 % 弧度,顯示此兩組梁柱接頭均具有優良的塑性變形能力。本研究依據有限的試驗結果初步證實,在適當設計下,此種型式的梁柱接頭將可以發揮良好的耐震性能。zh_TW
dc.description.abstractThe objective of this study is to investigate the seismic behavior of steel beam-to-SRC(Steel Reinforced Concrete)column connections. The reason of using the SRC column is to take its advantages of larger stiffness and compressive strength. Two full-size specimens were investigated through cyclic loading test. Both specimens were designed to meet the strong-column weak-beam requirement. The test results showed that the steel beams of all specimens developed excellent plastic rotation capacity. Satisfactory interstory drift angle up to 6% radians were observed from the tests. The test results also indicated that the reinforced concrete in the connection zone provided “effective constraint” to the steel beam which was embedded in the SRC column. This constraint had helped the steel beam to develop satisfactory plastic hinge right out of the SRC column face, and protected the welded joint from premature failure.en_US
dc.language.isozh_TWen_US
dc.subject鋼梁zh_TW
dc.subject包覆箱型鋼柱zh_TW
dc.subjectSRC柱zh_TW
dc.subject梁柱接頭zh_TW
dc.subject反復載重試驗zh_TW
dc.subject鋼梁塑性鉸zh_TW
dc.subject層間變位角zh_TW
dc.subject剪力釘zh_TW
dc.subject接頭區剪力強度zh_TW
dc.subject接頭區混凝土束制zh_TW
dc.subject耐震性能zh_TW
dc.subjectSteel Beamen_US
dc.subjectSRC Columnen_US
dc.subjectConnectionen_US
dc.subjectFull-size Specimenen_US
dc.subjectCyclic Loading Testen_US
dc.subjectPlastic Hingeen_US
dc.subjectSeismic Behavioren_US
dc.title鋼梁與包覆箱型鋼柱接合之梁柱接頭耐震試驗zh_TW
dc.titleSEISMIC BEHAVIOR OF STEEL BEAM TO STEEL REINFORCED CONCRETE (SRC) COLUMN CONNECTIONSen_US
dc.typeThesisen_US
dc.contributor.department土木工程學系zh_TW
顯示於類別:畢業論文


文件中的檔案:

  1. 653501.pdf
  2. 653502.pdf
  3. 653503.pdf
  4. 653504.pdf
  5. 653505.pdf
  6. 653506.pdf
  7. 653507.pdf
  8. 653508.pdf
  9. 653509.pdf
  10. 653510.pdf
  11. 653511.pdf
  12. 653512.pdf
  13. 653513.pdf
  14. 653514.pdf
  15. 653515.pdf
  16. 653516.pdf
  17. 653517.pdf
  18. 653518.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。