標題: | Comparison of cleanroom samplers for inorganic airborne molecular contaminants |
作者: | Lin, I-Kai Bai, Hsunling Liu, Cheng-Chang Wu, Bi-Jun 環境工程研究所 Institute of Environmental Engineering |
關鍵字: | airborne molecular contamination (AMC);cleanroom;micro-contamination;semiconductor device;diffusion denuder sampler (DDS);impinger air sampler |
公開日期: | 1-三月-2008 |
摘要: | The performances of inorganic airborne molecular contaminants (AMCs) via silica gel tubes, impingers, and diffusion denuder sampler (DDS) were compared in a cleanroom. The results showed silica gel tubes were not applicable for cleanroom sampling due to high blanks. While with optimal sampling conditions both impingers and DDS have much better performances, of which DDS has the lowest detection limits of the method for HF, HCl, HNO2, HNO3, SO2, and NH3 gases to be 0.15, 0.11, 0.13, 0.03, 0.07, and 0.42 mu g/m(3), respectively. Results indicated no significant difference for the HF and SO42- concentrations made by the DDS and impingers. |
URI: | http://dx.doi.org/10.1080/01496390701870580 http://hdl.handle.net/11536/9643 |
ISSN: | 0149-6395 |
DOI: | 10.1080/01496390701870580 |
期刊: | SEPARATION SCIENCE AND TECHNOLOGY |
Volume: | 43 |
Issue: | 4 |
起始頁: | 842 |
結束頁: | 861 |
顯示於類別: | 期刊論文 |