<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css"> Skip to main content

92% High Efficiency and Low Current Mismatch Interleaving Power Factor Correction Controller With Variable Sampling Slope and Automatic Loading Detection Techniques

Abstract

This paper proposes the dual nondeadtime variable sampling slope technique to carry out precise phase sensing and suppress phase error in interleaving power factor correction (PFC) controller over a whole ac switching cycle for low current mismatch. Furthermore, the proposed automatic loading detection (ALD) technique can keep efficiency higher than 92% over a wide load range due to accurately controlling the ON/OFF of dual phases. The test circuit fabricated in the TSMC 0.5-mu m 800-V UHV process shows that the highly integrated interleaving PFC can deliver a high power of 180 W and a high efficiency of 95% at an output power of 180 W.

Description

Citation

Endorsement

Review

Supplemented By

Referenced By