Abstract
This paper proposes the dual nondeadtime variable sampling slope technique to carry out precise phase sensing and suppress phase error in interleaving power factor correction (PFC) controller over a whole ac switching cycle for low current mismatch. Furthermore, the proposed automatic loading detection (ALD) technique can keep efficiency higher than 92% over a wide load range due to accurately controlling the ON/OFF of dual phases. The test circuit fabricated in the TSMC 0.5-mu m 800-V UHV process shows that the highly integrated interleaving PFC can deliver a high power of 180 W and a high efficiency of 95% at an output power of 180 W.