標題: A closed form solution for constant flux pumping in a well under partial penetration condition
作者: Yang, SY
Yeh, HD
Chiu, PY
環境工程研究所
Institute of Environmental Engineering
公開日期: 19-May-2006
摘要: [ 1] An analytical model for the constant flux pumping test is developed in a radial confined aquifer system with a partially penetrating well. The Laplace domain solution is derived by the application of the Laplace transforms with respect to time and the finite Fourier cosine transforms with respect to the vertical coordinates. A time domain solution is obtained using the inverse Laplace transforms, convolution theorem, and Bromwich integral method. The effect of partial penetration is apparent if the test well is completed with a short screen. An aquifer thickness 100 times larger than the screen length of the well can be considered as infinite. This solution can be used to investigate the effects of screen length and location on the drawdown distribution in a radial confined aquifer system and to produce type curves for the estimation of aquifer parameters with field pumping drawdown data.
URI: http://dx.doi.org/10.1029/2004WR003889
http://hdl.handle.net/11536/12240
ISSN: 0043-1397
DOI: 10.1029/2004WR003889
期刊: WATER RESOURCES RESEARCH
Volume: 42
Issue: 5
結束頁: 
Appears in Collections:Articles


Files in This Item:

  1. 000238016700001.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.