完整後設資料紀錄
DC 欄位語言
dc.contributor.authorAmer, Mohammeden_US
dc.contributor.authorWang, Chi-Chuanen_US
dc.date.accessioned2018-08-21T05:54:02Z-
dc.date.available2018-08-21T05:54:02Z-
dc.date.issued2017-06-01en_US
dc.identifier.issn1364-0321en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.rser.2017.01.120en_US
dc.identifier.urihttp://hdl.handle.net/11536/145499-
dc.description.abstractThis study reviewed the defrosting techniques applicable for the heating, ventilation, air-conditioning, and refrigeration industry, including passive, active, and system techniques. The passive methods normally use treated surfaces by changing the surface morphology through micro-grooved, anti-frost coating, hydrophilic, hydrophilic, or superhydropholic coating. For passive defrosting techniques, the microgrooved surfaces can improve the drainage of the frost melt effectively. It is generally agreed that the superhydropholic coating can delay the initialization of frosting and provides less water adhesion during defrosting. Yet defrosting performance for hydrophobic surfaces outperforms hydrophilic and uncoated surfaces. Active and system techniques, including electrohydrodynamic (EHD), low-frequency oscillation, and ultrasonic vibration methods, hot gas reverse cycle, electric heater, desiccant dehumidifiers and controlling strategies are reviewed. The EHD defrosting method is proved to be comparatively effective in natural or laminar flow operation. Test results also indicate that utilization of alternative current source is superior to the direct current source. The electrode with negative polarity is better than positive polarity as far as frost accumulation is concerned. The low-frequency oscillation is ineffective in defrosting while ultrasonic vibration provides effective frost removal and can delay the frost growth appreciably. Test results indicate that the ultrasonic oscillation poses considerable positive influence on defrosting either operated continuously or intermittently, in direct contact or not. For system defrosting, the hot gas reverse cycle is comparatively expensive to install but the efficiency, COP, and energy consumption are superior to the other system methods. Desiccants, either solid or liquid, can be employed in association with the system defrosting methods to lower energy consumption. There were various controlling strategies to detect the frost formation and to decide the best time to initiate defrosting. However, many of them were applicable to some specific systems and environments and require further investigations to test the relevant reliability, stability, and repeatability.en_US
dc.language.isoen_USen_US
dc.subjectPassive defrostingen_US
dc.subjectSystem defrostingen_US
dc.subjectActive defrostingen_US
dc.subjectSurface treatmenten_US
dc.subjectElectrohydrodynamics (EHD)en_US
dc.subjectUltrasonic vibrationen_US
dc.subjectReverse cycleen_US
dc.subjectControlling strategyen_US
dc.subjectElectrical resistant defrostingen_US
dc.titleReview of defrosting methodsen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.rser.2017.01.120en_US
dc.identifier.journalRENEWABLE & SUSTAINABLE ENERGY REVIEWSen_US
dc.citation.volume73en_US
dc.citation.spage53en_US
dc.citation.epage74en_US
dc.contributor.department機械工程學系zh_TW
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.identifier.wosnumberWOS:000401204700006en_US
顯示於類別:期刊論文