標題: Design and In Vivo Verification of a CMOS Bone-Guided Cochlear Implant Microsystem
作者: Qian, Xin-Hong
Wu, Yi-Chung
Yang, Tzu-Yi
Cheng, Cheng-Hsiang
Chu, Hsing-Chien
Cheng, Wan-Hsueh
Yen, Ting-Yang
Lin, Tzu-Han
Lin, Yung-Jen
Lee, Yu-Chi
Chang, Jia-Heng
Lin, Shih-Ting
Li, Shang-Hsuan
Wu, Tsung-Chen
Huang, Chien-Chang
Wang, Sung-Hao
Lee, Chia-Fone
Yang, Chia-Hsiang
Hung, Chung-Chih
Chi, Tai-Shih
Liu, Chien-Hao
Ker, Ming-Dou
Wu, Chung-Yu
電子工程學系及電子研究所
電機工程學系
Department of Electronics Engineering and Institute of Electronics
Department of Electrical and Computer Engineering
關鍵字: Active rectifier;bone-guided;cochlear implant;inductive link power supply;implantable medical devices
公開日期: 1-十一月-2019
摘要: Objective: To develop and verify a CMOS bone-guided cochlear implant (BGCI) microsystem with electrodes placed on the bone surface of the cochlea and the outside of round window for treating high-frequency hearing loss. Methods: The BGCI microsystem consists of an external unit and an implanted unit. The external system-on-chip is designed to process acoustic signals through an acquisition circuit and an acoustic DSP processor to generate stimulation patterns and commands that are transmitted to the implanted unit through a 13.56 MHz wireless power and bidirectional data telemetry. In the wireless power telemetry, a voltage doubler/tripler (2X/3X) active rectifier is used to enhance the power conversion efficiency and generate 2 and 3 V output voltages. In the wireless data telemetry, phase-locked loop based binary phase-shift keying and load-shift keying modulators/demodulators are adopted for the downlink and uplink data through high-Q coils, respectively. The implanted chip with four-channel high-voltage-tolerant stimulator generates biphasic stimulation currents up to 800 mu A. Results: Electrical tests on the fabricated BGCI microsystem have been performed to verify the chip functions. The in vivo animal tests in guinea pigs have shown the evoked third wave of electrically evoked auditory brainstem response waveforms. It is verified that auditory nerves can be successfully stimulated and acoustic hearing can be partially preserved. Conclusion and Significance: Different from traditional cochlear implants, the proposed BGCI microsystem is less invasive, preserves partially acoustic hearing, and provides an effective alternative for treating high-frequency hearing loss.
URI: http://dx.doi.org/10.1109/TBME.2019.2901374
http://hdl.handle.net/11536/153365
ISSN: 0018-9294
DOI: 10.1109/TBME.2019.2901374
期刊: IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume: 66
Issue: 11
起始頁: 3156
結束頁: 3167
顯示於類別:期刊論文