完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Fang, Wai-Chi | en_US |
dc.contributor.author | Huang, Hsiang-Cheh | en_US |
dc.contributor.author | Tseng, Shao-Yen | en_US |
dc.date.accessioned | 2014-12-08T15:29:22Z | - |
dc.date.available | 2014-12-08T15:29:22Z | - |
dc.date.issued | 2013-04-01 | en_US |
dc.identifier.issn | 0957-4174 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1016/j.eswa.2012.08.042 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/21158 | - |
dc.description.abstract | The worldwide population of people over the age of 65 has been predicted to more than double from 1990 to 2025. Therefore, ubiquitous health-care systems have become an important topic of research in recent years. In this paper, an integrated system for portable electrocardiography (ECG) monitoring, with an on-board processor for time-frequency analysis of heart rate variability (HRV), is presented. The main function of proposed system comprises three parts, namely, an analog-to-digital converter (ADC) controller, an HRV processor, and a lossless compression engine. At the beginning, ECG data acquired from front-end circuits through the ADC controller is passed through the HRV processor for analysis. Next, the HRV processor performs real-time analysis of time-frequency HRV using the Lomb periodogram and a sliding window configuration. The Lomb periodogram is suited for spectral analysis of unevenly sampled data and has been applied to time-frequency analysis of HRV in the proposed system. Finally, the ECG data are compressed by 2.5 times using the lossless compression engine before output using universal asynchronous receiver/transmitter (UART). Bluetooth is employed to transmit analyzed HRV data and raw ECG data to a remote station for display or further analysis. The integrated ECG health-care system design proposed has been implemented using UMC 90 nm CMOS technology. (C) 2012 Elsevier Ltd. All rights reserved. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | ECG | en_US |
dc.subject | Heart rate variability | en_US |
dc.subject | Integrated health-care system | en_US |
dc.subject | Portable system | en_US |
dc.subject | Lomb periodogram | en_US |
dc.title | Design of heart rate variability processor for portable 3-lead ECG monitoring system-on-chip | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/j.eswa.2012.08.042 | en_US |
dc.identifier.journal | EXPERT SYSTEMS WITH APPLICATIONS | en_US |
dc.citation.volume | 40 | en_US |
dc.citation.issue | 5 | en_US |
dc.citation.spage | 1491 | en_US |
dc.citation.epage | 1504 | en_US |
dc.contributor.department | 電子工程學系及電子研究所 | zh_TW |
dc.contributor.department | Department of Electronics Engineering and Institute of Electronics | en_US |
dc.identifier.wosnumber | WOS:000314737600008 | - |
dc.citation.woscount | 1 | - |
顯示於類別: | 期刊論文 |