Title: | Second-order approximations for RLC trees |
Authors: | Lin, CA Wit, CH 電控工程研究所 Institute of Electrical and Control Engineering |
Keywords: | model reduction;reduced-order systems;resistance-inductance-capacitance;(RLC) trees |
Issue Date: | 1-Jul-2004 |
Abstract: | We propose two-pole one-zero second-order approximations for transfer functions in resistance-inductance-capacitance trees. The approximation matches the first three moments of the original transfer function. Formulas for computing step-response parameters such as delay time, rise time, overshoot, etc., are given. Simulation results show that adding the zero improves accuracy of the approximation. |
URI: | http://dx.doi.org/10.1109/TCAD.2004.829794 http://hdl.handle.net/11536/26618 |
ISSN: | 0278-0070 |
DOI: | 10.1109/TCAD.2004.829794 |
Journal: | IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS |
Volume: | 23 |
Issue: | 7 |
Begin Page: | 1124 |
End Page: | 1128 |
Appears in Collections: | Articles |