標題: Optimal sampling conditions for a commonly used charge-coupled device camera in the full-field heterodyne interferometry
作者: Hsieh, Hung-Chih
Wu, Wang-Tsung
Chang, Wei-Yao
Chen, Yen-Liang
Su, Der-Chin
光電工程學系
Department of Photonics
關鍵字: CCD camera;Nyquist sampling rate;full-field heterodyne interferometry;three-parameter sine fitting algorithm
公開日期: 1-Apr-2011
摘要: The processes to derive the associated phase of an interference signal from the data of a series of recorded frames are performed, and we find that the sampling frequency being lower than the Nyquist sampling rate can also be applied to the full-field heterodyne interferometry. Two optimal sampling conditions for a commonly used CCD camera are proposed based on the relation between the heterodyne frequency and the contrast of the interference signal under the condition that the phase error is set to be 0.05 deg. (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.356712]
URI: http://dx.doi.org/10.1117/1.3567172
http://hdl.handle.net/11536/9028
ISSN: 0091-3286
DOI: 10.1117/1.3567172
期刊: OPTICAL ENGINEERING