标题: | 预力预铸自行复位建筑构架设计与耐震性能 Seismic Design and Performance of Post-tensioned Self-centering Buildings |
作者: | 陈俊翰 Jun-Hen Chen 刘俊秀 周中哲 Gin-Show Liou Chung-Che Chou 土木工程学系 |
关键字: | 预力;自复位;构架设计;梁柱接头;滑动支承;Post-tensioned;Self-centering;Frame Design;Beam Column Connection;Sliding Device |
公开日期: | 2010 |
摘要: | 预力预铸自复位构架是利用后拉预力工法提供梁与柱或柱与基础结合时所需的预力,此种形式的抗弯矩构架已发展成为可替代传统抗弯构架的新建筑结构,在以往的研究中不乏针对预力梁柱接头的研究。本研究建议梁柱及柱底接头均采预力接合以避免接头区产生残余变形,且楼板仅与预力构架单跨接合传递地震产生的楼层侧力,以避免楼板对预力构架产生束制效应,此外针对预力界面开合造成柱对梁产生的束制效应,提出以柱整体变形之挠曲劲度计算柱束制对梁产生的轴向压力增量,并提出预力预铸自行复位构架的设计方法及设计流程。 当预力抗弯构架中柱的数量为两支以上时,梁柱界面因开合效应产生的间隙会受到柱的束制,进而影响梁轴力的变化。本研究提出以预力建筑构架中每一楼层开合效应对柱产生的变形,计算柱的挠曲劲度及梁轴向压力的方法。由三层楼预力建筑构架的电脑模型分析中显示为了符合柱的整体变形,一楼处梁轴向压力会较钢腱拉力大,但在二楼与三楼处会较小。由三层楼两跨建筑物中撷取两跨一楼的构架试体进行试验,以验证本方法的准确性;试验中梁翼加劲板的细节在考虑柱顶无束制与柱顶为铰接的情形下,发现梁轴力较钢腱拉力分别增加2 %与60 %,此结果指出若二楼层处柱假设为铰接时,柱会提供过大的束制行为造成高估预力构架中梁轴力,因此,假设柱在楼层中为铰接的方式,并不适用于预测柱在预力建筑构架整体侧向变形时产生的挠曲劲度及轴力。 本研究建议一种楼板的接合细节,使得楼板在与预力构架接合时可提供滑动行为,并降低楼板限制预力构架伸展时产生的束制效应,并以缩尺两跨一层楼的预力构架试体进行震动台地震测试。结构体包含一组预力构架(PT Frame)及两组承重构架(Gravitational Frame),其中两承重构架是由钢梁、钢柱与铰支承以铰接方式接合,仅提供垂直向重力支撑,并分别平行放置预力构架的两侧,楼板与承重构架间以剪力钉固接,但仅与预力构架一跨的钢梁以剪力钉接合,为使楼板能在预力构架上产生滑动,在楼板梁与预力构架间提供滑动支承,并分别以1994年北岭地震(CNP196)与1999年集集地震(TCU074)对缩尺构架试体的耐震性能进行测试。在楼板无损害的情况下,预力构架的侧向位移与承重构架的侧向位移相似,且都拥有自行复位的能力。构架试体在加载1999年最大地表加速度1830 gal的集集地震时,构架的最大侧位移角为7.2%,可观察到梁下翼板靠近柱面承压处产生挫屈,并造成柱与梁上初始预力分别下降50%与21%,但构架试体的残余变形量仅约0.01%。 为验证依照本研究建议之设计方法设计之预力预铸构架能符合设计规范要求,分别以5个地震共15组测站之地表加速度测试预力预铸构架,同时,比较在相同的梁柱尺寸下,不同柱底及梁柱接头的构架在地震反应下的结果,并针对各楼层的位移、残余变形、加速度及消释能量进行比较,以判别各式构架的优劣情形。 The first generation for the post-tensioned (PT) self-centering (SC) system, which incorporates the PT technology to beam-to-column connections, exhibits good seismic performance with small residual deformations except for the first floor. Instead of using the fixed column base, the column PT to the base affects the seismic performance of frames, especially for residual deformations. A primary design procedure used for SC system was roughly described in this study. Cyclic tests on post-tensioned (PT) beam-to-column connections have demonstrated self-centering capabilities with gap opening, closing at the beam-to-column interface. Gaps, however, between beam-to-column interfaces in a real PT self-centering frame with more than one column are constrained by the columns, which causes beam compression force different from the applied PT force. This study presents an analytical method for evaluating column bending stiffness and beam compression force by modeling column deformation according to gap-openings at all stories. The predicted compression forces in the beams are validated by a cyclic analysis of a three-story PT frame, which is modeled with numerous axial springs in connections to capture the gap-opening behavior of the frame, and by cyclic tests of a full-scale, two-bay by first-story PT frame, which represents a substructure of the three-story PT frame. The proposed method shows that compared to the beam strand tensile force, the beam compression force is increased at the 1st story but is decreased at the 2nd and 3rd stories due to column deformation compatibility. The PT frame tests demonstrate that the proposed method reasonably predicts beam compression force and strand force. Test results also show that beam compression force is 2% and 60% larger than the beam strand force with respect to a minor restraint and a pin-supported boundary condition, respectively, at the tops of the columns. This indicates that assuming a pin-supported boundary condition at the upper story column can cause inaccurate estimation of column bending stiffness and beam compression force. This study proposes slab details, which allow for sliding of the slab and minimize restraints on the expansion of the PT frame. A composite slab is rigidly connected to the beams in only one bay of the PT frame. A sliding device is provided between the floor beams and the PT beams in other bays, where sliding of the slab is allowed. Several shake table tests were conducted on a reduced-scale, two-by-two bay one-story specimen model, which was composed of one PT frame and two gravitational frames. The scaled specimen model was excited by the 1994 Northridge and 1999 Chi-Chi earthquakes to examine its seismic performance. A PT frame and gravitational frames possessed the self-centering capability throughout the tests, responding in phase with minor differences in peak drifts due to the expansion of the PT frame. When the specimen was excited by the 1999 Chi-Chi earthquake with a peak ground acceleration of 1830 gal, the maximum interstory drift was 7.2%. Buckling of the beam bottom flange was observed near the compression toe, and the initial post-tensioning force decreased 50% and 22% in the columns and beams, respectively. However, the specimen remained operable and its residual drift was 0.01%. A three-dimensional analytical model with rotational springs in the PT connection and PT column base was introduced to capture shake table test results of the frame subassembly. The same modeling approach was adopted to one MRF and three SC frames to study the effects of column base on the seismic response of frames under the design based and maximum considered earthquakes. The monotonic, cyclic pushover, and time-history analyses were conducted for these frames. Analytical results showed that (1) the residual drift of the first floor could be significantly minimized by using the PT column base but the maximum interstory drift in the SC frame increased with decreasing fixity at the column base, (2) the largest maximum interstory drifts of the SC frames were larger than those of the MRF due to the low-to-medium structural period and high yield strength, and (3) the SC frame with the PT column base effectively decreased column restraining forces to the first floor compared to that with the fixed column base. |
URI: | http://140.113.39.130/cdrfb3/record/nctu/#GT079716801 http://hdl.handle.net/11536/44889 |
显示于类别: | Thesis |
文件中的档案:
If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.